{"id":4368,"date":"2015-04-02T10:08:15","date_gmt":"2015-04-02T14:08:15","guid":{"rendered":"http:\/\/regulatory.blog\/?p=4368"},"modified":"2020-01-29T13:35:32","modified_gmt":"2020-01-29T18:35:32","slug":"sds-research-for-osha-hazcom-2012","status":"publish","type":"post","link":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/","title":{"rendered":"SDS Research for OSHA HazCom 2012"},"content":{"rendered":"<h2>The Next Revolutionary War?<\/h2>\n<p>For many, this transition period to OSHA HazCom 2012 from the Hazard Communication Standard of 1994 can best be summarized by Thomas Paine\u2019s famous quote, \u201cThese are the times that try men\u2019s souls.\u201d\u00a0While it was used in the pamphlet <span style=\"text-decoration: underline\">The American Crisis<\/span> to deliver the ideas of the Revolution to the people of early America, there are many in the throes of classifying chemicals, substances and mixtures that feel this quote applies to daily life.<\/p>\n<p>There is pressure on SDS authors, either internally or externally, to \u201cget it right\u201d.\u00a0How can we be sure our classification is accurate? Did we cover all the hazards? Did we use the correct data?\u00a0 Should we check other sources? These last two questions can be the most difficult to answer.<br \/>\n<!--more--><\/p>\n<p>To be a \u201cgood\u201d SDS writer, never stop at just one source of data. Since OSHA chose not to use the exact language out of GHS Revision 3 and only selected certain building blocks when developing HazCom2012, care should be taken when utilizing classifications from other world areas. One has to remember that many other world areas did the same thing. Using classifications derived under another country\u2019s system could lead to some over-classification, or under, depending on which country\u2019s system is used.<\/p>\n<p>A prime example of this would be Toluene. A straightforward colorless, insoluble, liquid chemical used mostly as a solvent, and a fuel and builder molecule for other chemicals. It is also an aromatic hydrocarbon. So what\u2019s the problem?\u00a0The problem comes in when comparing the classifications from two reliable agencies.<\/p>\n<p><strong>Comparison:<\/strong><\/p>\n<p>According to the European Chemicals Agency (ECHA), Toluene is classified as the following:<\/p>\n<ul>\n<li>Flammable Liquid, Category 2<\/li>\n<li>Reproductive Toxicity, Category 2<\/li>\n<li>Aspiration Hazard, Category 1<\/li>\n<li>STOT \u2013 RE, Category 2<\/li>\n<li>Skin Irritant, Category 2<\/li>\n<li>STOT \u2013 SE, Category 3<\/li>\n<\/ul>\n<p>Looking at New Zealand&#8217;s Chemical Classification and Information Database (CCID) and the needed correlation sheet (found here)\u00a0suggests that Toluene is:<\/p>\n<ul>\n<li>Flammable Liquid, Category 2<\/li>\n<li>Acutely Toxic, Category 4 via Oral and Inhalation<\/li>\n<li>Skin Irritant, Category 2<\/li>\n<li>Eye Irritant, Category 2A<\/li>\n<li>Reproductive Toxicity, Category 2<\/li>\n<li>Aquatic Toxicity (Acute), Category 2<\/li>\n<li>Aquatic Toxicity (Chronic), Category 4<\/li>\n<\/ul>\n<p>There is inconsistency in the Acute Toxicity and Eye Irritation, as well as for Aspiration and Aquatic Hazards. Neither agency should be considered wrong or right. In this instance the answer lies in searching other reliable resources. In the end additional research can ensure a more comprehensive classification for chemical SDS and label. This does require more time, effort, and skill, but worker safety is what\u2019s most important.<\/p>\n<p>There is no need for a Revolution under HazCom2012. Only a commitment to good research and the time to perform it can truly prevent it.<\/p>\n<p>As always, ICC Compliance Center is here to help with all of your HazCom 2012 needs.<\/p>\n<p><span style=\"text-indent: 20px;width: auto;padding: 0px 4px 0px 0px;text-align: center;font: bold 11px\/20px 'Helvetica Neue',Helvetica,sans-serif;color: #ffffff;background: #bd081c  no-repeat scroll 3px 50% \/ 14px 14px;cursor: pointer\">Save<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Next Revolutionary War? For many, this transition period to OSHA HazCom 2012 from the Hazard Communication Standard of 1994&#8230;<\/p>\n","protected":false},"author":12544,"featured_media":5790,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[2536],"tags":[2391,2443,2524,2530,2531,2701],"class_list":["post-4368","post","type-post","status-publish","format-standard","has-post-thumbnail","category-osha-hazcom","tag-un-model-regulations","tag-safety","tag-msds","tag-labels","tag-osha","tag-hazcom-2012"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada<\/title>\n<meta name=\"description\" content=\"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"\/ca\/wp-json\/wp\/v2\/posts\/4368\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada\" \/>\n<meta property=\"og:description\" content=\"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/\" \/>\n<meta property=\"og:site_name\" content=\"ICC Compliance Center Inc - Canada\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/compliancecenter\" \/>\n<meta property=\"article:published_time\" content=\"2015-04-02T14:08:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-01-29T18:35:32+00:00\" \/>\n<meta name=\"author\" content=\"The Compliance Center\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ICC_Compliance\" \/>\n<meta name=\"twitter:site\" content=\"@ICC_Compliance\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"The Compliance Center\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/\"},\"author\":{\"name\":\"The Compliance Center\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/person\\\/d0cdb81394af683d8752dcd70e83f0fa\"},\"headline\":\"SDS Research for OSHA HazCom 2012\",\"datePublished\":\"2015-04-02T14:08:15+00:00\",\"dateModified\":\"2020-01-29T18:35:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/\"},\"wordCount\":462,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"UN Model Regulations\",\"safety\",\"MSDS\",\"labels\",\"OSHA\",\"Hazcom 2012\"],\"articleSection\":[\"OSHA HazCom\"],\"inLanguage\":\"en-CA\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/\",\"name\":\"SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2015-04-02T14:08:15+00:00\",\"dateModified\":\"2020-01-29T18:35:32+00:00\",\"description\":\"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#breadcrumb\"},\"inLanguage\":\"en-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/sds-research-for-osha-hazcom-2012\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SDS Research for OSHA HazCom 2012\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#website\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\",\"name\":\"ICC Compliance Center Inc - Canada\",\"description\":\"Hazmat Regulations Experts\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\",\"name\":\"ICC Compliance Center\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/04\\\/icc-compliance-center.png\",\"contentUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/04\\\/icc-compliance-center.png\",\"width\":500,\"height\":120,\"caption\":\"ICC Compliance Center\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/compliancecenter\",\"https:\\\/\\\/x.com\\\/ICC_Compliance\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/icccompliancecenter\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/person\\\/d0cdb81394af683d8752dcd70e83f0fa\",\"name\":\"The Compliance Center\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g\",\"caption\":\"The Compliance Center\"},\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/author\\\/the-compliance-center\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada","description":"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"\/ca\/wp-json\/wp\/v2\/posts\/4368","og_locale":"en_US","og_type":"article","og_title":"SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada","og_description":"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.","og_url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/","og_site_name":"ICC Compliance Center Inc - Canada","article_publisher":"https:\/\/www.facebook.com\/compliancecenter","article_published_time":"2015-04-02T14:08:15+00:00","article_modified_time":"2020-01-29T18:35:32+00:00","author":"The Compliance Center","twitter_card":"summary_large_image","twitter_creator":"@ICC_Compliance","twitter_site":"@ICC_Compliance","twitter_misc":{"Written by":"The Compliance Center","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#article","isPartOf":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/"},"author":{"name":"The Compliance Center","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/person\/d0cdb81394af683d8752dcd70e83f0fa"},"headline":"SDS Research for OSHA HazCom 2012","datePublished":"2015-04-02T14:08:15+00:00","dateModified":"2020-01-29T18:35:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/"},"wordCount":462,"commentCount":0,"publisher":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#primaryimage"},"thumbnailUrl":"","keywords":["UN Model Regulations","safety","MSDS","labels","OSHA","Hazcom 2012"],"articleSection":["OSHA HazCom"],"inLanguage":"en-CA","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/","url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/","name":"SDS Research for OSHA HazCom 2012 - ICC Compliance Center Inc - Canada","isPartOf":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#primaryimage"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#primaryimage"},"thumbnailUrl":"","datePublished":"2015-04-02T14:08:15+00:00","dateModified":"2020-01-29T18:35:32+00:00","description":"Researching chemical hazard data for compliant SDS is not a simple process. We discuss important issues and information about compliant SDS authoring.","breadcrumb":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#breadcrumb"},"inLanguage":"en-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/"]}]},{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/sds-research-for-osha-hazcom-2012\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.thecompliancecenter.com\/ca\/"},{"@type":"ListItem","position":2,"name":"SDS Research for OSHA HazCom 2012"}]},{"@type":"WebSite","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#website","url":"https:\/\/www.thecompliancecenter.com\/ca\/","name":"ICC Compliance Center Inc - Canada","description":"Hazmat Regulations Experts","publisher":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.thecompliancecenter.com\/ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-CA"},{"@type":"Organization","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization","name":"ICC Compliance Center","url":"https:\/\/www.thecompliancecenter.com\/ca\/","logo":{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/logo\/image\/","url":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/04\/icc-compliance-center.png","contentUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/04\/icc-compliance-center.png","width":500,"height":120,"caption":"ICC Compliance Center"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/compliancecenter","https:\/\/x.com\/ICC_Compliance","https:\/\/www.youtube.com\/user\/icccompliancecenter"]},{"@type":"Person","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/person\/d0cdb81394af683d8752dcd70e83f0fa","name":"The Compliance Center","image":{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/secure.gravatar.com\/avatar\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ffaf61fd5f777c226b3def14f826dd70ff3c31d271395e89a28cd22f597ef2b5?s=96&d=mm&r=g","caption":"The Compliance Center"},"url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/author\/the-compliance-center\/"}]}},"_links":{"self":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts\/4368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/users\/12544"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/comments?post=4368"}],"version-history":[{"count":0,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts\/4368\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/media?parent=4368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/categories?post=4368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/tags?post=4368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}