{"id":5269,"date":"2020-11-10T09:00:58","date_gmt":"2020-11-10T14:00:58","guid":{"rendered":"https:\/\/www.thecompliancecenter.com\/blog\/?p=5269"},"modified":"2025-09-08T01:19:26","modified_gmt":"2025-09-08T05:19:26","slug":"light-my-fire-calculating-flash-points-for-flammable-liquids","status":"publish","type":"post","link":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/","title":{"rendered":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids"},"content":{"rendered":"<p><em>This post was originally published in February 2016 and has been updated in November 2020 for accuracy.<\/em><\/p>\n<p><span style=\"font-weight: 400;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-874743 size-full\" src=\"https:\/\/www.thecompliancecenter.com\/wp-content\/uploads\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png\" alt=\"\" width=\"1001\" height=\"301\" \/><\/span><\/p>\n<p><span style=\"font-weight: 400;\">One of the most common tests for determining hazard classification is the flashpoint. This humble piece of physical information is defined in various ways in various regulations, but generally is the lowest temperature at which the vapors from a flammable liquid will ignite near the surface of the liquid or in a test vessel. This can be critical for safety because this temperature will be the lowest possible for the liquid to cause a flash fire if released or spilled. The fire risk will be much smaller if the material can be handled and transported at temperatures lower than the flashpoint.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The flashpoint has become the standard test for classifying flammable liquids. It\u2019s used by the U.S. OSHA (Occupational Health and Safety Act) and HMR (Hazardous Materials Regulations) classification systems, as well as Canada\u2019s WHMIS (Workplace Hazardous Materials Information System) and TDG (Transportation of Dangerous Goods Regulations).<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Obtaining a flashpoint on a new product is usually easy enough. Many laboratories, particularly those that deal with petrochemicals, can perform the test for a reasonable charge. If your company has too many products to make outsourcing practicable, a flashpoint tester itself is comparatively low cost (as scientific apparatus goes), and a trained person can obtain data quickly and efficiently. However, both of these options do cost money. Wouldn\u2019t it be nice if there were a way to avoid the expense?<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For example, toxic materials are usually classified by a test called the LD50 (the lethal dose to 50% of test subjects). This is a more expensive, complicated test, but there\u2019s one beautiful feature for mixtures. You don\u2019t have to do the test if you can calculate it. This calculation basically prorates the LD50s of the ingredients based on their concentrations. While there is debate about how accurate this system is, it\u2019s directly mentioned in the above regulations as an option if testing of the actual product has not been done.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Unfortunately, the same regulations do not directly provide us with a method for calculating a flashpoint. But OSHA and WHMIS are based on the Globally Harmonized System of Classification and Labelling, and TDG and the HMR are based on the UN Recommendations on the Transport of Dangerous Goods. Both of these documents include a reference to calculating flashpoints if directly measured ones are not available.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">That\u2019s the good news. The bad news starts when we discover that both the Globally Harmonized System and the UN Recommendations don\u2019t give the specific formula for the calculation. The GHS reference can be found in sub-section 2.6.4.2.2, while the UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria places the reference to a calculation in Appendix 6, paragraph 4. At least both of them refer to the same method, one reported by Gmehling and Rasmussen in the journal Industrial &amp; Engineering Chemistry Fundamentals 21, 86, (1982) titled \u201cFlashpoints of flammable liquid mixtures using UNIFAC.\u201d<\/span><\/p>\n<p><span style=\"font-weight: 400;\">When we look up this article, we encounter another roadblock \u2013 like many scientific journals, this one is not free, and the article is behind a paywall. We have a choice; either pay up to read the full article or see if the formula appears somewhere else.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Oh, and it helps if we know what UNIFAC is. Apparently, the acronym stands for \u201cUNIQUAC Functional-group Activity Coefficients\u201d (making it an acronym containing an acronym) and is \u201ca semi-empirical system for the prediction of non-electrolyte activity in non-ideal mixtures.\u201d<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A little more digging on the internet comes up with an article summarizing how to calculate various flammability measurements, published by M. Hristova and S. Tchaoushev in the Journal of the University of Chemical Technology and Metallurgy, 41, 3, 2006, 291-296, titled \u201cCalculation of Flash Points and Flammability Limits of Substances and Mixtures.\u201d This can be accessed, with no paywall,<\/span><span style=\"font-weight: 400;\">\u00a0<a href=\"https:\/\/dl.uctm.edu\/journal\/node\/j2006-3\/04-Hristova-291-296.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">here<\/a>.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">So, we finally have our method to calculate our flashpoints. Except it\u2019s nothing like the relatively simple method for calculating LD50s. Hristova and Tschaoushev tell us the calculation will take four steps:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Determine the flashpoint which satisfies an equation relating \u201cthe actual partial pressure of component i in a vapor-air mixture\u201d with \u201cthe partial pressure in a gas-air mixture with a composition corresponding to the LFL (lower flammable limit) of pure component i.\u201d<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Determine the flammability limits at the temperature under study using the Zebatekis equation. (This equation is helpfully included.)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Determine the partial pressure of each component using the Antoine equation, and<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Determine the activity coefficients using the UNIFAC method.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Easy, right?<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At this point, it becomes obvious that these calculations are currently of use, perhaps, to physical chemists but are not yet a workable solution for companies simply trying to determine if their product is in Packing Group II or III. It turns out that the molecular forces in flammable liquids are far too complex to reduce to a simple equation such as can be used for toxic mixtures. Even computer systems that model these mixtures must be taken as provisional and certainly not nearly as reliable as measured data.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">So, the day when we can toss aside our flash point testers and classify flammable liquids based only on the composition is yet to come. A measured flashpoint is still the simplest and most accurate solution to comply with the classification rules for workplace safety or transportation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Do you have any questions about classifying hazardous materials? Contact ICC Compliance Center at 888-442-9628 (U.S.) or 888-977-4834 (Canada), and ask for one of our regulatory experts.<\/span><\/p>\n<p><a href=\"https:\/\/www.thecompliancecenter.com\/ca\/newsletter-signup\/\"><span style=\"font-weight: 400;\">Stay up to date and sign up for our newsletter!<br \/>\n<\/span><\/a><\/p>\n<p><em><strong>We have all the products, services and training you need to ensure your staff is properly trained and informed.<\/strong><\/em><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td><a href=\"https:\/\/www.thecompliancecenter.com\/ca\/product-category\/publications\/canadian-tdg\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-thumbnail wp-image-855648\" src=\"https:\/\/www.thecompliancecenter.com\/wp-content\/uploads\/2012\/04\/BK-CLTJE-150x150.png\" alt=\"\" width=\"150\" height=\"150\" \/><\/a><br \/>\n<a href=\"https:\/\/www.thecompliancecenter.com\/ca\/product-category\/publications\/canadian-tdg\/\">Canadian TDG Publications<\/a><\/td>\n<td><a href=\"https:\/\/www.thecompliancecenter.com\/ca\/product-category\/publications\/ghs-publications\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-thumbnail wp-image-207421\" src=\"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-150x150.png\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-150x150.png 150w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-300x300.png 300w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-100x100.png 100w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-140x140.png 140w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-500x500.png 500w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-350x350.png 350w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS-64x64.png 64w, https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/01\/ICC_Publications_GHS.png 601w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><br \/>\n<a href=\"https:\/\/www.thecompliancecenter.com\/ca\/product-category\/publications\/ghs-publications\/\">GHS Publications<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>This post was originally published in February 2016 and has been updated in November 2020 for accuracy. One of the&#8230;<\/p>\n","protected":false},"author":12546,"featured_media":858710,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[2402,2413,2508,2536,2661,3047,4008,4037,5069,5072,5073,5074,5080,5081],"tags":[2362,2364,2366,2368,2407,2429,2443,2496,2502,2525,2531,2574,2636,2648,3003],"class_list":["post-5269","post","type-post","status-publish","format-standard","has-post-thumbnail","category-safety-2","category-tdg-regulation-updates","category-whmis-2015","category-osha-hazcom","category-49-cfr-regulation-updates","category-packaging-updates","category-ground-road-and-rail-transport","category-compliance-training","category-ground-transportation","category-workplace-safety","category-dot-49-cfr","category-tdgr","category-osha","category-whmis","tag-dangerous-goods","tag-hazmat","tag-tdg","tag-49-cfr","tag-dot","tag-regulations","tag-safety","tag-shipping","tag-ghs","tag-sds","tag-osha","tag-hazardous-materials","tag-workplace-safety","tag-hazcom","tag-whmis"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC<\/title>\n<meta name=\"description\" content=\"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"\/ca\/wp-json\/wp\/v2\/posts\/5269\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC\" \/>\n<meta property=\"og:description\" content=\"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/\" \/>\n<meta property=\"og:site_name\" content=\"ICC Compliance Center Inc - Canada\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/compliancecenter\" \/>\n<meta property=\"article:published_time\" content=\"2020-11-10T14:00:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-08T05:19:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1001\" \/>\n\t<meta property=\"og:image:height\" content=\"301\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Barbara Foster\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ICC_Compliance\" \/>\n<meta name=\"twitter:site\" content=\"@ICC_Compliance\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Barbara Foster\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/\"},\"author\":{\"name\":\"Barbara Foster\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/person\\\/b0dcc6206e95e81b691d25512e856fbb\"},\"headline\":\"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids\",\"datePublished\":\"2020-11-10T14:00:58+00:00\",\"dateModified\":\"2025-09-08T05:19:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/\"},\"wordCount\":968,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/02\\\/ICC_CalculatingFlashPoint_Blog_9-2021.png\",\"keywords\":[\"dangerous goods\",\"hazmat\",\"TDG\",\"49 CFR\",\"DOT\",\"Regulations\",\"safety\",\"shipping\",\"GHS\",\"SDS\",\"OSHA\",\"hazardous materials\",\"workplace safety\",\"hazcom\",\"whmis\"],\"articleSection\":[\"Safety\",\"Transportation of Dangerous Goods\",\"WHMIS 2015\",\"OSHA HazCom\",\"49 CFR\",\"UN Packaging\",\"Ground (road and rail) Transport\",\"Compliance &amp; Training\",\"Ground Transportation\",\"Workplace Safety\",\"DOT 49 CFR\",\"TDGR\",\"OSHA\",\"WHMIS\"],\"inLanguage\":\"en-CA\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/\",\"name\":\"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/02\\\/ICC_CalculatingFlashPoint_Blog_9-2021.png\",\"datePublished\":\"2020-11-10T14:00:58+00:00\",\"dateModified\":\"2025-09-08T05:19:26+00:00\",\"description\":\"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#breadcrumb\"},\"inLanguage\":\"en-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/02\\\/ICC_CalculatingFlashPoint_Blog_9-2021.png\",\"contentUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/02\\\/ICC_CalculatingFlashPoint_Blog_9-2021.png\",\"width\":1001,\"height\":301},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/light-my-fire-calculating-flash-points-for-flammable-liquids\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#website\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\",\"name\":\"ICC Compliance Center Inc - Canada\",\"description\":\"Hazmat Regulations Experts\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#organization\",\"name\":\"ICC Compliance Center\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/04\\\/icc-compliance-center.png\",\"contentUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/04\\\/icc-compliance-center.png\",\"width\":500,\"height\":120,\"caption\":\"ICC Compliance Center\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/compliancecenter\",\"https:\\\/\\\/x.com\\\/ICC_Compliance\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/icccompliancecenter\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/#\\\/schema\\\/person\\\/b0dcc6206e95e81b691d25512e856fbb\",\"name\":\"Barbara Foster\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-CA\",\"@id\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/03\\\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/03\\\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg\",\"contentUrl\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/03\\\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg\",\"caption\":\"Barbara Foster\"},\"description\":\"Barbara Foster graduated from Dalhousie University with a Master\u2019s degree in Chemistry and a Bachelor\u2019s degree in Education. As one of ICC Compliance Center\u2019s most senior employees, she has worked in the Toronto office for the past three decades as a Regulatory Affairs Specialist and Trainer. She is fluent in various US, Canadian, and international regulations involving transportation, including TDG, 49 CFR, ICAO, IMDG, and the ADR\\\/RID. She also specializes in the hazard communication standards of OSHA, WHMIS, CCCR, and the Globally Harmonized System for Classification and Labelling (GHS). Barbara is the author of ICC\u2019s TDG Clear Language Driver and Handler\u2019s Guide. Currently, she is a participant on the Canadian General Standards Board committee where she creates training standards for transportation of dangerous goods in Canada and is a past Chair of the Dangerous Goods Advisory Council.\",\"url\":\"https:\\\/\\\/www.thecompliancecenter.com\\\/ca\\\/help-center\\\/articles\\\/author\\\/barbara-foster\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC","description":"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"\/ca\/wp-json\/wp\/v2\/posts\/5269","og_locale":"en_US","og_type":"article","og_title":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC","og_description":"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?","og_url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/","og_site_name":"ICC Compliance Center Inc - Canada","article_publisher":"https:\/\/www.facebook.com\/compliancecenter","article_published_time":"2020-11-10T14:00:58+00:00","article_modified_time":"2025-09-08T05:19:26+00:00","og_image":[{"width":1001,"height":301,"url":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png","type":"image\/png"}],"author":"Barbara Foster","twitter_card":"summary_large_image","twitter_creator":"@ICC_Compliance","twitter_site":"@ICC_Compliance","twitter_misc":{"Written by":"Barbara Foster","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#article","isPartOf":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/"},"author":{"name":"Barbara Foster","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/person\/b0dcc6206e95e81b691d25512e856fbb"},"headline":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids","datePublished":"2020-11-10T14:00:58+00:00","dateModified":"2025-09-08T05:19:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/"},"wordCount":968,"commentCount":0,"publisher":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png","keywords":["dangerous goods","hazmat","TDG","49 CFR","DOT","Regulations","safety","shipping","GHS","SDS","OSHA","hazardous materials","workplace safety","hazcom","whmis"],"articleSection":["Safety","Transportation of Dangerous Goods","WHMIS 2015","OSHA HazCom","49 CFR","UN Packaging","Ground (road and rail) Transport","Compliance &amp; Training","Ground Transportation","Workplace Safety","DOT 49 CFR","TDGR","OSHA","WHMIS"],"inLanguage":"en-CA","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/","url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/","name":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids | ICC","isPartOf":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#primaryimage"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#primaryimage"},"thumbnailUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png","datePublished":"2020-11-10T14:00:58+00:00","dateModified":"2025-09-08T05:19:26+00:00","description":"Flash points can be calculated, instead of measured. But just how easy, let alone accurate, are these calculations?","breadcrumb":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#breadcrumb"},"inLanguage":"en-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/"]}]},{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#primaryimage","url":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png","contentUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2016\/02\/ICC_CalculatingFlashPoint_Blog_9-2021.png","width":1001,"height":301},{"@type":"BreadcrumbList","@id":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/light-my-fire-calculating-flash-points-for-flammable-liquids\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.thecompliancecenter.com\/ca\/"},{"@type":"ListItem","position":2,"name":"\u201cLight My Fire\u201d \u2013 Calculating Flash Points for Flammable Liquids"}]},{"@type":"WebSite","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#website","url":"https:\/\/www.thecompliancecenter.com\/ca\/","name":"ICC Compliance Center Inc - Canada","description":"Hazmat Regulations Experts","publisher":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.thecompliancecenter.com\/ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-CA"},{"@type":"Organization","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#organization","name":"ICC Compliance Center","url":"https:\/\/www.thecompliancecenter.com\/ca\/","logo":{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/logo\/image\/","url":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/04\/icc-compliance-center.png","contentUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2020\/04\/icc-compliance-center.png","width":500,"height":120,"caption":"ICC Compliance Center"},"image":{"@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/compliancecenter","https:\/\/x.com\/ICC_Compliance","https:\/\/www.youtube.com\/user\/icccompliancecenter"]},{"@type":"Person","@id":"https:\/\/www.thecompliancecenter.com\/ca\/#\/schema\/person\/b0dcc6206e95e81b691d25512e856fbb","name":"Barbara Foster","image":{"@type":"ImageObject","inLanguage":"en-CA","@id":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2023\/03\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg","url":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2023\/03\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg","contentUrl":"https:\/\/www.thecompliancecenter.com\/ca\/wp-content\/uploads\/sites\/4\/2023\/03\/BarbaraFoster_Jan2023-scaled-e1679516761809-100x100.jpg","caption":"Barbara Foster"},"description":"Barbara Foster graduated from Dalhousie University with a Master\u2019s degree in Chemistry and a Bachelor\u2019s degree in Education. As one of ICC Compliance Center\u2019s most senior employees, she has worked in the Toronto office for the past three decades as a Regulatory Affairs Specialist and Trainer. She is fluent in various US, Canadian, and international regulations involving transportation, including TDG, 49 CFR, ICAO, IMDG, and the ADR\/RID. She also specializes in the hazard communication standards of OSHA, WHMIS, CCCR, and the Globally Harmonized System for Classification and Labelling (GHS). Barbara is the author of ICC\u2019s TDG Clear Language Driver and Handler\u2019s Guide. Currently, she is a participant on the Canadian General Standards Board committee where she creates training standards for transportation of dangerous goods in Canada and is a past Chair of the Dangerous Goods Advisory Council.","url":"https:\/\/www.thecompliancecenter.com\/ca\/help-center\/articles\/author\/barbara-foster\/"}]}},"_links":{"self":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts\/5269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/users\/12546"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/comments?post=5269"}],"version-history":[{"count":0,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/posts\/5269\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/media\/858710"}],"wp:attachment":[{"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/media?parent=5269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/categories?post=5269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thecompliancecenter.com\/ca\/wp-json\/wp\/v2\/tags?post=5269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}